DSO-8000
USB Oscilloscope
USB Spectrum Analyzer
|
500MSa
1Mpt buffer
Advanced triggering
|
|
|
|
The DSO-8502 Oscilloscope operates at up to 500 MSa/s with a
1Mpt buffer. Other features include a FFT Spectrum Analyzer, XY plot
and Advanced triggering.
|
|
Features |
 |
 |
 |
|
 |
 |
Advanced Triggering DSO
- Level
- Multi-channel
- Pulse width
- Pulse count
- Filter
- TV
The high-speed circuit allows you to
sample at full speed( up to 500MSa) while triggering on various TV
sync signals including individual scan line.
- Adjustable position



|
 |
|
Deep Acquisition Memory
DSO-8502
|
1 Million point buffer on 1 channel at
a sample rate of 500MSa/S.
512K point buffer on 2 channels at sample rates of 250MSa/S
and below.
|
DSO-8202
|
128K point buffer on 2 channels at
sample rates of 200MSa/S and below.
|
Much longer than
standard Oscilloscopes which enables you to capture more waveform
details without sacrificing overall recording time. Longer capture
buffers give you the flexibility to use faster sample rates and still
capture for extended periods of time.
“The big buffer really saved me.
With my last oscilloscope I always had to balance recording time and
time per division. With Link’s scope I can record at the fast
sampling rate and still see the entire event.” Bob Mitchell,
consultant. (beta tester)”
|
|
 |
Channel History - Similar
to Persistence mode, but much better.
The Oscilloscope can automatically save and display up to 30 previous captures.
Each capture will be color
coded with the oldest ones fading to white.
|
 |
 |
Auto-Setup
With one mouse click the DSO
will analyze incoming signals and setup the oscilloscope using advanced
analysis routines.
|
 |
 |
Spectrum Analyzer/FFT
- The DSO also delivers high accuracy spectrum analysis.
- Unlike swept spectrum analyzers which require a stable repetitive signal, the DSO-8000 can also analyze a single shot event.
- FFT information can be saved to disk and exported to other programs such as Excel, Mathcad, etc...
|
 |
 |
XY
Oscilloscope plot
|
- XY Area (Lissajous curve)
- Angle
- Radius
- Delta X
- Delta Y
|
|
 |
 |
Oscilloscope Probes
Two 1x/10x switchable probes are
included with the
oscilloscope.
We also sell the following types of probes:
|
 |
 |
Waveform Measurements
|

- Powerful cursors display voltage and time information.
- Advanced waveform measurements.
-
PASS/FAIL testing based on the results of those measurements
is also available. Traces can be logged to disk automatically
on PASS or FAIL.
|
- Area
- Cycles
- Delay
- Delta delay
- Dutycycle
- Fall time
- Frequency
- Maximum
- Mean
- Median
- Minimum
- Peak to peak
- Period
- Phase
- Pulse width
- Rise time
- Rms voltage
- Rms voltage (AC)
- XY Area
- XY Angle
- XY Radius
|
|
 |
 |
Easy Installation
The
PC Based oscilloscope connects to the USB port of your computer. To install the oscilloscope all you need to do is plug it into your PC, plug in the power supply and
install the software.
The DSO is about the size of a video tape (7" x 3.75" x 1.5"). If you need portability what could be easier than connecting the DSO to your laptop?
|
 |
 |
Simple Operation
- Installation is a snap.
- Make measurements in your first half hour.
- Simple controls make operation intuitive.
- Perform sophisticated operations that you couldn't even dream of doing with a knob based DSO.
- Save default setups to disk for easy recall at a future date. You don't need to keep a notepad with settings scribbled in it. Just save them to the file name of your choice.
-
Data and settings are easily saved to disk.
- Screen shots can be pasted into documents and annotated in your favorite image editing
program.
|
 |
 |
Battery power or wall power
Wall power
Most people will power their DSO with the included wall adapter.
Battery power
The case has a battery holder for 4 AA batteries (NiMH recommended). Using AA batteries allows you to use the DSO away
from a power source without draining your laptop's battery.
|
 |
 |
Automatic Storage
To save time, you can automatically datalog your waveforms to your PC.
The data logger can also store only waveforms meeting specific
parameter criteria, such as rise times between 20 and 30ns and pulse
widths greater than 100ms, etc....
|
 |
 |
The Windows Oscilloscope software takes advantage of your computer's large color screen.
You can display any
combination of Digital Oscilloscope and Spectrum Analyzer traces simultaneously.
Color can be a real
time saver. Each display element can be a unique color. This includes
each of the Traces, Memories, Cursors, Text, Background,
Grid and more.
Stand-alone oscilloscope display
screens represent a compromise at best. Few people would choose a 7" or 9"
monitor as the screen for their PC. So why use a small monitor for an oscilloscope? Link
PC Based instruments let you choose the display monitor size and type for viewing your
traces. Plus, you can utilize powerful PC-industry display peripherals such as projectors, remote monitors, and heads-up displays.
Many people are now using dual monitor PC's - our software will work
there also - Imagine having a 30" wide trace window.
You can take
electronic snapshots of the screen and put them into your documents as
well as print to your standard windows printer.
|
 |
"zoom-and-scroll" simplifies trouble shooting and analysis. The display shows the entire recorded waveform(s).
In addition, the user can zoom (up to 50X) on signal details and
scroll through long records to identify and characterize problems. The
deep memory allows analysis of jitter from the beginning of the record
to the end.
|
 |
The speed of your PC does not significantly affect the performance of our instruments
Although we rely on the PC for display and for the user interface.
We don't rely on it for our high speed acquisition. If your PC is fast
enough and has enough memory to run windows well it will run our
products well also. All of the high speed acquisition is done in
Oscilloscope.
The
Instrument has high speed samplers and buffers. It can acquire at up to
500MSa/s*1 and stores the data in it's own 1 MegaSample*1
data buffer. When these buffers are full everything is transferred to
the PC.
|
 |
 |
Software Libraries (optional)
If you want to write your own software to drive the unit, our
optional
DLL or LabView drivers
are available for purchase.
|
 |
 |
|
Specifications
|
 |
 |
 |
| |
DSO-8502
|
DSO-8202
|
|
Input |
|
|
Max Sample Rate
|
500MSa/s on
1 ch.
250MSa/s on 2 ch.
|
200MSa/s on 2 ch.
|
Bandwidth
|
100MHz
|
100MHz
|
Inputs
|
2 + External
|
2 + External
|
Gain Range (per division) full scale = 10 divisions
|
Probe
|
Voltage
per division
|
Full scale voltage
|
1x
|
5mV to 5V per division
|
50mV to 50V
|
10x
|
50mV to
50V per division
|
500mV to 500V
|
100x
|
500mV to 500V per division
|
5V to 5000V
|
|
Probe
|
Voltage
per division
|
Full scale voltage
|
1x
|
10mV to 5V per division
|
100mV to 50V
|
10x
|
100mV to 50V per division
|
1V to 500V
|
100x
|
1V to 500V per division
|
10V to 5000V
|
|
Max Input Voltage (at BNC connector)
|
max input voltage at probe tip depends on probe type (1x, 10x, 100x, etc.)
Probe
|
Continuous
|
Transient
(DC + AC <10KHz)
|
BNC
|
± 50V DC
|
± 150V DC
|
1X probe:
|
± 50V DC
|
± 150V DC
|
10X probe:
|
± 500V DC
|
± 1,500V DC
|
100X probe:
|
± 5,000V DC
|
± 15,000V DC
|
1000X probe:
|
± 50,000V DC
|
± 150,000V DC
|
|
Vertical Resolution
|
8 bits/ch.
|
Vertical Range
|
10 divisions
|
External Trigger
|
TTL level (1.4V) Max voltage: 5V
|
Offset Range
|
± 5 divisions
|
Coupling
|
AC, DC, and Ground
|
Offset Resolution
|
0.04 division increments
|
Impedance
|
1MΩ // 15pF
|
DC Accuracy
|
± 2%
|
A/D
|
Dual 8 bit
|
Probes
|
1x/10x switchable with standard BNC connector. Two probes are included.
100x probes are available as an option
|
Timebase
|
|
Rate
|
500MSa/s... 5Sa/s
2ns/sample to 5s/sample
2ns/division to 20secons/division
|
200MSa/s... 5Sa/s
5ns/sample to 5s/sample
5ns/division to 20secons/division
|
Accuracy
|
+/- 0.01%
|
Resolution
|
2ns
|
5ns
|
Skew
|
< 1ns
|
Memory
|
|
Buffer Size
|
1 Million
points/ch.(1 ch. mode)
512K points/ch.(2 ch. mode)
|
128K points/ch. (2 ch.mode)
|
Calibration
|
|
Oscilloscope
|
Self calibrating
|
Probe
|
Calibration signal provided
|
| |
|
Trigger |
|
Type
|
Rising Edge
(Adjustable level),
Falling Edge (Adjustable level),
TV-H,
TV-V,
Pulse Width,
Pulse Count,
Pulse Width & Pulse Count
|
External In
|
Yes
|
External Out
|
Yes
|
Rising Edge
|
Yes
|
Falling Edge
|
Yes
|
Pulse Count
|
Yes
|
Pulse Width
|
Yes
|
Pulse Width & Count
|
Yes
|
TV Horizontal
|
Yes
|
TV Vertical
|
Yes
|
Out
|
Yes
|
Mode
|
Auto, Normal, and Single
|
Autosetup
|
Yes
|
Slope
|
Rising or Falling
|
Level
|
Adjustable
|
Range (vertical)
|
10 divisions
|
Resolution
|
0.04 division increments
|
|
Software |
|
Windows XP/2K/Vista
|
Yes
|
FFT
|
Yes
|
XY Plot
|
Yes
|
Math
|
Yes
|
Advanced Math
|
Yes
|
Pass/Fail Testing
|
Yes
|
Data Logging (based on pass/fail test)
(on every capture)
|
Yes
Yes
|
|
Physical |
|
Interface
|
USB 2.0
|
Probes
|
Two 1x/10x switchable probes are included.
|
BNC Connectors
|
4 total: 2 input, Trig-in and trig-out
|
Calibration point
|
Yes
|
Power Requirement
|
5V at 750mA (Typical)
Wall power or battery power (NiMH recommended)
|
Dimensions
|
7" x 3.75" x 1.5"
|
|
 |
 |
 |
 |
 |
|
Prices
|
 |
 |
 |
 |
 |
DSO-8502
 |
DSO-8202 |
DSO Kit: Oscilloscope,
two 1x/10x probes, USB cable, US power supply, software

|
DSO-8502
Non U.S. customers add $38 for universal power supply (90-240V 50-60Hz)
|
DSO-8202 Non U.S.
customers add $38 for universal power supply (90-240V 50-60Hz)
|
|
 |
 |
 |
 |
 |
|
Optional Accessories
|
 |
|
 |